Standards

ASTM C14M - 07


ASTM C14M - 07 Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe [Metric]


Active Standard ASTM C14M Developed by Subcommittee: C13.01 |Book of Standards Volume: 04.05

more info 5 pages $ 36.00
more info 5 pages $ 36.00
why redline? 10 pages $ 43.20

Historical(view previous versions of standard) ASTM License Agreement

Description Related Products

ASTM C14M

Abstract

This specification covers nonreinforced concrete sewer, storm drain, and culvert pipe. The pipe manufactured according to this specification shall be of three classes: Class 1, Class 2, and Class 3. The strength requirements for nonreinforced concrete pipe are specified. The concrete shall consist of cementitious material, mineral aggregates, and water. Cementitious materials are the following: cement, fly ash, ground granulated blast furnace slag, and allowable combinations of cementitious materials. The design of the pipe may be according to design tables or modified or special design. The following are the processes for pipe manufacturing: mixture; curing such as pipe curing, water curing, and membrane curing; and specials like shapes or fittings and fabricated branches. The following tests shall be made: strength test, absorption test, permeability test, and hydrostatic test.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.

1.2 This specification is the metric counterpart of Specification C 14. Note 1 - This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.


2. Referenced Documents

C1116 Specification for Fiber-Reinforced Concrete and Shotcrete
C150 Specification for Portland Cement
C309 Specification for Liquid Membrane-Forming Compounds for Curing Concrete
C33 Specification for Concrete Aggregates
C443M Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets [Metric]
C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile [Metric]
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Ground Granulated Blast-Furnace Slag for Use in Concrete and Mortars


Index Terms

concrete sewer; culvert; nonreinforced; pipe; storm drain


DOI: 10.1520/C0014M-07

ASTM International is a member of CrossRef.


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions