A Biaxial Fatigue Machine for Elevated Temperature Testing
Brown, MW
Senior research fellow and professor,
Sheffield University,
Miller, KJ
Senior research fellow and professor,
Sheffield University,
Abstract
A biaxial fatigue rig has been developed to study failure under low cycle fatigue conditions. The tubular specimen can be subjected to axial load, torque, and internal pressure enabling a wide range of stress/strain states to be obtained under strain-controlled conditions. A four zone furnace has been developed for elevated temperature tests, while allowing strains to be measured from the gauge length.
Keywords:
cyclic loads, temperature control, extensometers, fatigue tests, elevated temperature, plastic deformation, strain measurement, temperature measurement, test specimens, triaxial tests